IITEMA   27339
INSTITUTO DE INVESTIGACIONES EN TECNOLOGIAS ENERGETICAS Y MATERIALES AVANZADOS
Unidad Ejecutora - UE
artículos
Título:
Rotor fault diagnosis in permanent magnet synchronous machine using the midpoint voltage of windings
Autor/es:
BOSSIO, JOSÉ; BOSSIO, GUILLERMO; VERUCCHI, CARLOS; RUSCHETTI, CRISTIAN; DE ANGELO, CRISTIAN
Revista:
IET ELECTRIC POWER APPLICATIONS
Editorial:
INST ENGINEERING TECHNOLOGY-IET
Referencias:
Año: 2020 vol. 14 p. 256 - 261
ISSN:
1751-8660
Resumen:
A new strategy is proposed here for the diagnosis of asymmetric demagnetisation in permanent magnet synchronousmachines. The strategy is based on the measuring of the voltage at the midpoint of the windings within a phase. Unlike thephase voltage, for a fault situation, the midpoint voltage shows sidebands around the fundamental component, which allowsdetecting and quantifying the demagnetisation phenomenon. A low-cost implementation for the automatic detection of faults isalso proposed in the present study and experimental results are presented to validate the strategy.