INVESTIGADORES
STOLOWICZ Fabiana Gisela
congresos y reuniones científicas
Título:
DEVELOPMENT OF A SIMPLIFIED MOLECULAR TEST OF CONGENITAL CHAGAS DISEASE FOR NEONATAL SCREENING
Autor/es:
LAROCCA LUCIANA; STOLOWICZ FABIANA; MACALLINI G; DIMA E; ARANDA C; VOJNOV ADRIAN; ONETO ADRIANA; CARRILLO CAROLINA
Lugar:
Mar del Plata
Reunión:
Congreso; LXI Reunión Científica de la Sociedad Argentina de Biología (SAIC); LXIV Reunión Anual de la Sociedad Argentina de Inmunología (SAI) y XLVIII Reunión Anual de la Sociedad Argentina de Farmacología Experimental (SAFE).; 2016
Institución organizadora:
SAIC
Resumen:
INTRODUCTION. Chagas disease is an American endemic caused by the protozoan parasite​Trypanosoma cruzi​ . The estimatednumberofannualcasesofcongenital​T.cruziinfectioninArgentinais1,200,butlessthan 400 are officially reported due to methodological limitations for early detection. OBJECTIVES. To develop a simple test for congenital Chagas detection based on a molecular isothermal amplification (AMI) adapted to simplified neonatal screening practices. MATERIALS & METHODS​.​Samples of negative or artificially inoculated bloodweredroppedontoGuthrietest cards and used as substrate for AMI reaction at predefined conditions (65°C - 40 min). It was determined: a Sensitivity, compared with a Quantitative Polymerase chain reaction (Q-PCR); and b- Specificity, challenging the reaction with other trypanosomatids, human and yeast DNA.The reaction efficiency pipetting the reagents separately vs a pre-prepared mix, and reading the result by lateral flow dipsticks chromatography (LFD) (field method) vs electrophoresis (analytical method) were also tested. Finally, AMI tests wereperformedwithblood samples of newborn babies delivered from not infected and infected mothers, in order to challenge the simplified AMI test in field conditions. RESULTS. a- Samples artificially inoculated with ​T. cruzi​ , showed a detection sensitivity by AMI of 1-10 parasites/sample, 1 to 10 times greater than with Q-PCR. The sensitivity was similar in LFD than electrophoresis and in this kind of simplified test, dispensed in mix reaction. b- In all cases, heterologous DNA samples were negative by AMI and Q-PCR. c- 1 of the 20 blood samples of newborn babies delivered from not infected mothers resulted positive by AMI (5%) and 95% resulted negative. CONCLUSIONS.​Our results indicate that AMI can yield a high specificity and sensitivity using adrieddropof bloodinaGuthriecardandpre-preparedmix,witharemarkablysimplertrialwithoutexperthumanresourcesor complex equipment.