INVESTIGADORES
PLATINO Manuel
artículos
Título:
Photovoltaic monitoring system for Auger Muons and Infill for the Ground Array
Autor/es:
ANGEL CANCIO; ALEXIS MANSILLA; JAVIER MAYA; BEATRIZ GARCIA; ALEJANDRO ALMELA; BELEN ANDRADA; ANA M. BOTTI; ALBERTO ETCHEGOYEN; JUAN M. FIGUEIRA; ALAN FUSTER; NICOLAS GONZALEZ; MATIAS ROLF HAMPEL; EWA HOLT; JOHANNES HULSMAN; MARIELA JOSEBACHUILI; NICOLAS LEAL; AGUSTÍN LUCERO; DIEGO MELO; SARAH MULLER; MATÍAS PERLIN; MANUEL PLATINO; DIEGO RAVIGNANI; MATIAS RONCORONI; FEDERICO SANCHEZ; CHRISTIAN SARMIENTO-CANO; DAVID SCHMIDT; GAIA SILLI; FEDERICO SUAREZ; ALVARO TABOADA; OSCAR WAINBERG; BRIAN WUNDHEILER; DIANA YELOS
Revista:
Energy & Science Engineering
Editorial:
Society of Chemical Industry and John Wiley & Sons, Ltd
Referencias:
Año: 2018
ISSN:
2050-0505
Resumen:
This study is devoted to characterizing the operation of the entire photovoltaic system installed in one of the Auger Muons and Infill for the Ground Array (AMIGA) stations, a complimentary detector for the Pierre Auger Observatory, the largest cosmic‐ray air shower array in the world, 3000 km2, powered exclusively by solar energy. To understand charge and discharge cycles, the whole system behavior under different climatic conditions and to determine its limitations, the design of a new prototype for monitoring the whole system online is a fundamental part of this contribution. Also, it is demonstrated that the configuration of solar charge controllers in parallel is able to manage panels of different powers and brands and that the monitoring system allows analyzing periods with adverse weather conditions.