INVESTIGADORES
FLORES LARSEN Silvana Elinor
artículos
Título:
Heat loss of a trapezoidal cavity absorber for a linear Fresnel reflecting solar concentrator
Autor/es:
FLORES LARSEN SILVANA; ALTAMIRANO M.; HERNÁNDEZ A.
Revista:
RENEWABLE ENERGY
Editorial:
PERGAMON-ELSEVIER SCIENCE LTD
Referencias:
Lugar: Amsterdam; Año: 2012 vol. 39 p. 198 - 206
ISSN:
0960-1481
Resumen:
The present paper studies the heat loss of a linear absorber with a trapezoidal cavity and a set of pipes used for a linear Fresnel reflecting solar concentrator. The study includes the measurements on a 1.4 m long prototype installed in a laboratory, and its thermal simulation in steady-state using EnergyPlus software. Results of the measured vertical temperature variation inside the cavity, the surface interior and exterior wall and window temperatures, the global heat loss at steady-state and the heat loss coefficients, are presented for six different temperatures of the pipes. Measurements revealed a stable thermal gradient in the upper portion of the cavity and a convective zone below it. Around 91% of the heat transferred to outdoors occurs at the bottom transparent window, for a pipe temperature of 200 C. The heat loss coefficient per area of absorbing pipes ranged from 3.39 W/m2K to 6.35 W/m2K (for 110 C < Tpipe < 285 C), and it increased with the increase of Tpipe. Simpler and less time-consuming available free software originally designed for heat transfer in buildings was tested to be a possible replacement of the highly complex CFD software commonly used to simulate the steady-state heat loss of the absorber. The experimental and predicted data sets were found to be in good agreement.