INFINA (EX INFIP)   05545
INSTITUTO DE FISICA INTERDISCIPLINARIA Y APLICADA
Unidad Ejecutora - UE
artículos
Título:
Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device.
Autor/es:
V. RASPA; C. MORENO
Revista:
PHYSICS LETTERS A
Editorial:
Elsevier
Referencias:
Año: 2009 vol. 373 p. 3659 - 3662
ISSN:
0375-9601
Resumen:
A radiographic method is proposed and then applied to infer the continuum part of the hard X-ray spectrum of a 4.7 kJ Plasma Focus from differential absorption measurements on metals. Copper, nickel, titanium and silver samples with thicknesses spanning between 0.1 and 10 mm were employed as filters. The X-ray radiation was detected using a standard radiographic screen-film system.  The results show the  presence of a dominant peak around 75 keV with significant spectral components in the range of 40 to 200 keV. The method is easy to  follow, inexpensive, and allows for calibrated, single shot, spectral  measurements.