Snapping scapular syndrome secondary to rib intramedullary fixation device
Autor/es:
ZAIDENBERG, EZEQUIEL E.; ROSSI, LUCIANO A.; BONGIOVANNI, SANTIAGO L.; TANOIRA, IGNACIO; MAIGNON, GASTON; RANALLETTA, MAXIMILIANO
Revista:
International Journal of Surgery Case Reports
Editorial:
Elsevier Ltd
Referencias:
Año: 2015 vol. 17
ISSN:
2210-2612
Resumen:
Background Scapulo-thoracic joint disorders, including bursitis and crepitus, are commonly misdiagnosed problems and can be a source of persistent pain and dysfunction Presentation of the case This article describes an unusual case of a snapping scapula syndrome secondary to a migration through the lateral cortex of a rib splint intramedullary fixation device into the scapulothoracic joint. Discussion Recently, the operative fixation of multiple ribs fractures with intramedullary fixation devices has become popular. Despite the good outcomes with new rib splint designs, concern remains about the potential complications related to potential loss of fracture reduction with migration of the wire resulting in pain or additional injury to the surrounding tissues. Conclusion Surgeons should pay attention to any protrusion of intramedullary rib implants, especially in the evaluation of routine X-rays following surgical treatment. We should be aware of the possibility of this rare cause of snapping scapula syndrome to avoid delayed diagnosis and consider removing the implant will resolve the pain.