Integration of Fricke gel dosimetry with Ag nanoparticles for experimental dose enhancement determination in theranostics
Autor/es:
J. VEDELAGO; F. MATTEA; M. VALENTE
Lugar:
Santo Domingo
Reunión:
Simposio; ISSSD 2017 - International Symposium of Solid State Dosimetry; 2017
Institución organizadora:
Univ. Aut. Sto Domingo & Univ. Aut. Méx
Resumen:
The use and implementation of nanoparticles in medicine has grown exponentially in the last twenty years. Their main applications include drug delivery, theranostics, tissue engineering and magneto function. Dosimetric techniques can take advantage of inorganic nanoparticles properties and their combination with gel dosimetry techniques could be used as a first step for their later inclusion in radio-diagnostics or radiotherapy treatments [1]. This work presents preliminary results of properly synthesized and purify silver nanoparticles integration with Fricke gel dosimeters. Used nanoparticles presented mean sizes ranging from 2 to 20 nm, with a lognormal distribution. Xylenol orange concentration in Fricke gel dosimeter was adjust in order to allow sample?s optical readout, accounting nanoparticles plasmon. Dose enhancement was assessed irradiating dosimeters setting X-ray beams energies below and above silver K-edge.