Resumen:
In this GAP note, we present the algorithm implemented in the electronics of theunderground muon detector (UMD) designed to extract calibration data for the ADCchannel. We aim to document this new feature, along with the tests performed priorto the integration into the standard firmware of the UMD electronics. We brieflydiscuss the parameters needed to set it up, along with the tools available to extractthese. Finally, we comment on the stability of the ADC calibration in the field andthe potential of the calibration for monitoring the detector performance.