Título:
Influence of procedure variables on C-Mn-Ni-Mo ANSI/AWS A5.29-98 E111T5-K3 metal cored
Autor/es:
ESTELA S. SURIAN, HERNÁN G. SVOBODA, NOEMÍ M. RAMINI DE RISSONE, LUIS A. DE VEDIA
Lugar:
Pine Mountain, USA
Reunión:
Congreso; Trends In Welding Research 2005; 2005
Institución organizadora:
American Society for Metals
Resumen:
The objective of this work was to study the effect that the utilization of different shielding gases  (CO2 and a mixture 80% Ar / 20%CO2), welding position (flat and vertical up), arc energy and number of passes per layer (2 and 3) have on the allweld metal microstructure and mechanical properties from an ANSI/AWS A5.29-98 E111T5-K3/K3M metal cored wire, 1.2 mm diameter. Hardness, tensile and impact tests were used to assess the mechanical properties and quantitative metallographic analysis were performed to identify the resulting microstructures. ANSI/AWS A5.29-98 E111T5-K3 tensile property requirements were satisfied under Ar/CO2 shielding and E111T5-K3 chemical composition specification was met in all conditions, except for Mo requirements, which maximum value was over passed. E111T5-K3 toughness requirements were comfortably satisfied under both gas types, but significant variations were found with different welding procedures. These variations have been rationalised in terms of the microstructure and chemical composition of the weld deposits. The results obtained in this work showed that, as in the case of SMAW electrodes of the type ANSI/AWS A5.5-96 E10018/11018/ 12018-M types, depositing C-Mn-Ni-Mo or C-Mn-Ni-Mo-Cr alloyed ferritic weld metal, the main difficulty resides in obtaining adequate tensile strength values rather than in satisfying toughness requirements that can be obtained almost in any welding condition, within the requirements of the appropriate standard.