INVESTIGADORES
HANSEN Patricia Maria
artículos
Título:
Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers
Autor/es:
THE PIERRE AUGER COLLABORATION (P HANSEN PERTENECE A LA COLABORACIÓN AUGER)
Revista:
JOURNAL OF INSTRUMENTATION
Editorial:
IOP PUBLISHING LTD
Referencias:
Lugar: Londres; Año: 2016 vol. 11 p. 1 - 30
ISSN:
1748-0221
Resumen:
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global PositioningSystem (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique tocorrect for the GPS drifts, and an independent method is used to cross-check that indeed we reach a nanosecond-scale timing accuracy by this correction. First, we operate a ?beacon transmitter? which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcats intercepted with a software-defined radio.From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.