Calibration of commercial MOSFETs as sensors for a low cost dosimeter for a CubeSat application
Autor/es:
MRODRIGUEZ CAÑETE, G. REDIN, J.LIPOVETZKY
Lugar:
Mendoza
Reunión:
Conferencia; Argentinian Conference on Micro-Nanoelectronics, Technology and Applications 2014. EAMTA/CAMTA; 2014
Institución organizadora:
IEEE
Resumen:
This work presents the calibration and selection of pMOS commercial transistors with 250nm thick oxides as sensors for a dosimeter. The thermal and radiation response of the devices is studied, to obtain a pre-calibration of each sensor and optimal reading of VT. The sensors will be used  in a CubeSat to measure  the absorbed dose during radiation experiments on modern devices.