IFLP   13074
INSTITUTO DE FISICA LA PLATA
Unidad Ejecutora - UE
congresos y reuniones científicas
Título:
Report on the design and test of liquid sample holder for SAXS measurements under static magnetic field
Autor/es:
D. F. CORAL; P. MENDOZA ZÉLIS; M.B. FERNÁNDEZ VAN RAAP
Lugar:
Campinas
Reunión:
Encuentro; 23 ava Reunión Annual de Usuarios del LNLS (23 ava RAU); 2013
Institución organizadora:
LNLS
Resumen:
Here, we aim to present the design and test of a sample holder for liquids to perform SAXS measurement under static magnetic ¯eld. This is a modi¯cation of the already existing holder available in SAXS2 beam line. The design was discussed at the last RAU [1], the construction is under progress nowadays and the implementation will be carried out under proposal D11A - SAXS1-13714 (Nov. 2012). This device can ¯nd applications in the study of induced anisotropy in colloidal magnetic dispersion and rheological problems, among others. The static magnetic field are produced with commercially available NdFeB magnets of remanent field Br=1.12 T. We have designed two distinct con¯gurations to achieve homogenous field, parallel and perpendicular to the beam direction. Also, the arrangements can be modify to vary the ¯eld intensity up to 0.7 T. We choose to keep the original material of the liquid sample holder (stainless steel 316L) because austenitic stainless steels are non-magnetic in the annealed, fully austenitic condition. The magnetic permeability of this material in this condition is generally less than 1.02 at 5 kA/m. To test the effectiveness of the field achieved with the projected magnets arrangements we choose the use of stable colloidal suspensions, consisting of single-domain spherical magnetic nanoparticles (NP) displaying very low polydispersity and dispersed in liquids. The mean primary particle sizes are in the range from 2 to 7 nm and coated with » 2 nm oleic acid shell. This ensemble exhibited a nice SAXS pattern [2], which is the result of primary particle pattern superimposed to the power law behavior originated at the NP self organization. [1]. Design of a sample holder for SAXS measurements under static magnetic field, Marcela B. Fern¶andez van Raap and P. Mendoza Z¶elis, Sessao SAXS1/SAXS2, 22a RAU (22 ava Reunion Annual de Usuarios del LNLS, Campinas Brazil) 28 e 29 de fevereiro de 2012. [2] M. B. Fernández van Raap, P. Mendoza Zélis, D. F. Coral, T. E. Torres,C. Marquina, G. F. Goya and F. H. Sánchez. Self organization in oleic acid-coated CoFe2O4 colloids: a SAXS study. Journal of Nanoparticle Research. Vol 14(9), pag.1072. 2012.